HNF01.1A-F240-R0065-A-480-NNNN

  • Rated 4.8 (12 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
  • MPN: R911306533
  • Stock: In-Stock, Ships 3-7 Days
  • Call for Expedited Shipping and Product Condition Options
The HNF01.1A-F240-R0065-A-480-NNNN Mains Filter is manufactured by Rexroth Indramat Bosch. This filter has an Industrial Area EMC Area Per DIN EN and a Regenerative Units only supply unit. The nominal current for this mains filter is 65 and the Mains Connecting Voltage is AC 400-480v.

Request a Quote Request Repair

Standard Repair Time is 1 - 2 weeks. 4 Day Rush Repair options are available.

✓ In-Stock!

HNF01.1A-F240-R0065-A-480-NNNN

  • Rated 4.8 (12 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
  • MPN: R911306533
  • Stock: In-Stock, Ships 3-7 Days
  • Call for Expedited Shipping and Product Condition Options
The HNF01.1A-F240-R0065-A-480-NNNN Mains Filter is manufactured by Rexroth Indramat Bosch. This filter has an Industrial Area EMC Area Per DIN EN and a Regenerative Units only supply unit. The nominal current for this mains filter is 65 and the Mains Connecting Voltage is AC 400-480v.

Request a Quote Request Repair

Standard Repair Time is 1 - 2 weeks. 4 Day Rush Repair options are available.

Warranty
1 Year Wake Industrial Warranty Included
Shipping
Worldwide shipping via DHL, UPS, and Fedex
Sell Us Your Surplus
Have a HNF01.1A-F240-R0065-A-480-NNNN to sell?
To Speak to a sales representative for pricing and lead time:

Product Description

Bosch Rexroth Group is a reputable company utilizing highly advanced technology and engineering techniques to manufacture and assemble various automation components such as drive controllers, motors, mains filters, and hydraulics. The systems are integrated and dynamic to suit various applications and ensure efficiency. When installed accordingly, Rexroth products are safe, durable and perform optimally. The components surpass the expected value in performance and durability. With a desire to see you enjoy these benefits, we have compiled a list of the technical information to help in the operation process.

We consider the HNF01.1A-F240-R0065-A-480-NNNN a mains filter model. It is a non-negotiable component as the main filters ensure you adhere to the EMC value ranges. The filters also suppress leakage of the current generated by the line capacitors through optimal coordination with other components such as power units, and power motor cables. When you need power cables, we have shielded cables that are compatible with your mains filters. Amazingly, you can even get up to 75 meters length of a single power cable at Rexroth. Therefore, you have no reason to get the non-compatible power cables that sometimes are not shielded properly. With our power cables, you are assured of trouble-free operation and conformity to the EN 61800-3 Group 2 and Class A.

During operation, the HNF01.1A-F240-R0065-A-480-NNNN dissipates power of 163W and runs at a normal continuous current of 65A. When it comes to the dimensions, HNF01.1A-F240-R0065-A-480-NNNN is 150mm wide, 440mm high and 262 mm deep. When manufactured this filter model weighs about 25kgs. This technical information is supposed to help you know the ideal transport and installation approaches and space. A skilled technician should be able to install the filters with ease.

HNF01.1A-F240-R0065-A-480-NNNN Documents

  • hnf01.1a-f240-r0065-a-480-nnnn
  • HNF011AF240R0065A480NNNN
  • HNF01 1A F240 R0065 A 480 NNNN

HNF01.1A-F240-R0065-A-480-NNNN Technical Specifications

EMC Area Per DIN EN: Industrial Area
Maximum Elevation Height: 1000 MSL
Nominal Current: 65 A
Power Dissipation: 163 W
Mains Connecting Voltage: 400 - 480 V
Width: 150 mm
Height: 440 mm
Depth: 262 mm
Weight: 25 kg
Maximum Allowable Humidity: 95%

Frequently Asked Questions about HNF01.1A-F240-R0065-A-480-NNNN


Q: What is the primary function of the HNF01.1A-F240-R0065-A-480-NNNN mains filter?

A: The HNF01.1A-F240-R0065-A-480-NNNN mains filter is crucial for ensuring adherence to EMC value ranges and suppressing leakage currents generated by line capacitors. It achieves this through optimal coordination with power units and motor cables.

Q: How does the HNF01.1A-F240-R0065-A-480-NNNN mains filter impact the selection of power cables?

A: This mains filter requires the use of shielded power cables to ensure compatibility and optimal performance. Rexroth provides shielded cables up to 75 meters in length, specifically designed to work with this filter.

Q: What are the power dissipation and continuous current specifications of the HNF01.1A-F240-R0065-A-480-NNNN?

A: The HNF01.1A-F240-R0065-A-480-NNNN dissipates 163W of power and operates at a normal continuous current of 65A. These specifications are critical for understanding the thermal and electrical load capabilities of the filter, ensuring it matches the system's requirements for efficient and safe operation.

Q: Why is it important to use a mains filter like HNF01.1A-F240-R0065-A-480-NNNN in a power system?

A: A mains filter like the HNF01.1A-F240-R0065-A-480-NNNN is essential for maintaining the stability and efficiency of a power system by controlling electromagnetic interference and current leakage. Its role in ensuring EMC compliance cannot be understated.

Q: Can the HNF01.1A-F240-R0065-A-480-NNNN mains filter be used with long power cables, and what are the benefits?

A: Yes, the HNF01.1A-F240-R0065-A-480-NNNN can be used with power cables up to 75 meters in length, available from Rexroth. This capability allows for greater flexibility in system design and layout, ensuring effective EMC compliance and operational reliability over extended distances.

Internal Product Review

  • ‘‘The HNF01.1A-F240-R0065-A-480-NNNN mains filter is an essential component for EMC compliance, efficiently handling a continuous current of 65 A, thereby ensuring system stability and safety.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo