The HMV01.1R-W0045-A-07-NNNN from Rexroth Indramat operates with a rated input voltage of 3 x AC 380-480 V. It provides an output current of 60.0 A, ensuring efficient power control.

Quote Request Form:

Warranty
Wake Industrial Warranty
To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HMV01.1R-W0045-A-07-NNNN is a reliable drive controller from Rexroth Indramat, known for its robust performance and high quality. The purpose of the drive controller is to facilitate effective control and management of power in various applications. The drive controller is ideal for a wide range of high-power tasks in contemporary automation systems, thanks to its rated input voltage of 3 x AC 380-480 V.

The HMV01.1R-W0045-A-07-NNNN is designed to be compact to allow for effortless integration into systems that are space-constrained. The drive controller measures 440 millimeters in height, 250 millimeters in width, and 262 millimeters in depth. The Rexroth Indramat controller has a weight of 20 kg. Regenerative cooling and forced ventilation are two methods that provide efficient cooling. These methods enable the equipment to operate continually without its temperature rising to an unsafe level. The maximum input current that the product can accept is 65 A, and it has an output current of 60 A while it is operating at 750 V DC. The stated power output of the device is 45 KW. With a bulk cooling capacity of 257 m^3/h, the device assures proper thermal management. The extreme short circuit current rate (SCCR) of 42,000 A rms provides excellent electrical safety. Safe operation needs a minimum of 300 mm of space at the top and 130 mm of space at the bottom for installation.

The normal operating temperature range is 0 to +40 degrees C, which allows for best performance in a variety of settings. Because of this, the drive controller can be used in many controlled settings. The HMV01.1R-W0045-A-07-NNNN drive controller is a reliable solution for maintaining efficiency in industrial automation processes.

Ambient temperature range
0 to +40 degrees C
Cooling type
Forced ventilation
Device dimensions (H x W x D)
440 mm x 250 mm x 262 mm
Mass
20.00 kg
Output voltage
750 V DC
Power consumption for control voltage
41 W
Power dissipation at continuous current
680 W
Rated input voltage
3 x AC 380-480 V
Short circuit current rating
42,000 A rms
Volumetric capacity of forced cooling
257 m^3/h
  • HMV01 1R W0045 A 07 NNNN
  • HMV011RW0045A07NNNN
  • hmv01.1r-w0045-a-07-nnnn
  • HMV1.1R-W0045-A-07-NNNN
Fault / Error Code What it means Recommended Corrective Action
F218 Supply-unit heat-sink temperature above shutdown limit Check cabinet airflow, clean or replace blower, wait until heat-sink < 45 °C, then perform Class 1 Reset
F226 DC-bus undervoltage while drives were enabled Verify mains for brown-outs; be sure “Drive Enable” drops before mains contactor; restore AC and reset fault 
F8025 Over-voltage in the power section (regenerative energy too high) Lengthen decel ramps or add / up-size braking resistor; clear fault when bus ≤ 730 V 
F8028 Over-current in power section Inspect motor & DC-bus cables for shorts, check mains choke, test IGBTs if fault repeats, then reset 
F8070 +24 V DC control-supply undervoltage Measure the 24 V rail, tighten X31 terminals, up-size PSU if it sags below 22.8 V, then clear fault 
F8091 Power section defective (hardware monitor trip) Run IndraDrive Diag self-test; if fault recurs, replace inverter power stage or send for repair 
F8838 Over-current in external braking resistor Check resistor Ω rating & wiring; size resistor for peak regen power; replace damaged unit, then reset 
F8813 Connection error – mains choke not detected Inspect choke wiring / ID plug, verify choke type in parameters, then power-cycle and test 
F2816 Soft-start fault in power-supply unit Inspect inrush-limiter circuit & mains contactor, cycle AC; if fault persists replace soft-start module
F8057 Device overload shutdown Check aggregate drive currents vs. 45 kW rating, balance axis duty-cycle, cool supply, then reset 
Supply Unit Type (R = regen, E = resistive) Rated Output Power (kW) Nominal DC-bus (V DC) Cooling Mode Key Notes
HMV01.1R-W0045-A-07-NNNN R (regenerative) 45 700 Internal blower Feeds braking energy back to mains; 60 A rated output
HMV01.1E-W0030-A-07-NNNN E (resistive) 30 700 Internal blower Standard rectifier; dissipates regen energy via resistor
HMV01.1E-W0075-A-07-NNNN E 75 700 Internal blower Higher-power non-regen infeed for large multi-axis systems 
HMV01.1E-W0120-A-07-NNNN E 120 700 Internal blower Top-end 120 kW supply; pairs with HMS/HMD high-current drives 
HMV01.1R-W0120-A-07-NNNN R 120 700 Internal blower Regenerative 120 kW variant for energy-intensive lines 
HMV01.1R-W0018-A-07-NNNN-AA R 18 700 Internal blower Compact 18 kW infeed for small cells or retrofits 
Error Code Meaning
F226 DC-bus undervoltage detected during operation
F8022 Encoder 1: signals incorrect (cable, shielding, or encoder fault)
F8025 Over-voltage in power section (regen energy too high)
F8028 Over-current in power section
F8057 Device overload shutdown (supply unit exceeded thermal/electrical limits)
F8060 Fast hardware trip – over-current
F8070 +24 V DC control-supply undervoltage
F8091 Power section defective (internal hardware monitor)
F8813 Connection error: mains choke not detected
F8838 External braking-resistor over-current

Frequently Asked Questions about HMV01.1R-W0045-A-07-NNNN:

Q: Why does HMV01.1R-W0045-A-07-NNNN use forced ventilation?

A: Forced ventilation ensures effective cooling, preventing overheating during continuous operation. It supports thermal management for extended device longevity.

Q: Why does HMV01.1R-W0045-A-07-NNNN have a short circuit rating?

A: The short circuit current rating of 42,000 A rms ensures high electrical protection. It safeguards the device from potential damage.

Q: What is the power dissipation of HMV01.1R-W0045-A-07-NNNN?

A: Power dissipation during continuous current operation is 680 W. This supports stable performance without significant energy loss in the system.

Q: What is the weight of HMV01.1R-W0045-A-07-NNNN?

A: The device weighs 20 kg. Its manageable size allows easy installation while supporting robust mechanical and electrical performance.

Q: What cooling capacity does HMV01.1R-W0045-A-07-NNNN offer?

A: The volumetric cooling capacity is 257 m^3/h. It maintains the required airflow to prevent overheating during continuous operation.


Internal Product Review

  • ‘‘The HMV01.1R-W0045-A-07-NNNN by Rexroth Indramat delivers outstanding performance with a rated input current of 65.0 A and a 750 V DC output voltage. Its compact design and volumetric cooling capacity of 257 m^3/h ensure optimal thermal management. The short circuit current rating adds solid protection.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo