The Bosch Rexroth Indramat HMF01.1N-S0K1-M0600-N-480-NNNN is part of the HMF Motor Filters series and is a sinusoidal filter with a rated current of 600 Amps and a voltage rating of 3 × AC 480 Volts. It features an overload capacity of 150% for 60 seconds, peak output frequency of 100 Hz, and uses surrounding air cooling. The filter supports free installation and is designed for use at altitudes up to 3000 meters.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HMF01.1N-S0K1-M0600-N-480-NNNN is a motor output filter produced by Bosch Rexroth Indramat and assigned to the HMF Motor Filters series. Installed between a servo drive and an induction or synchronous motor, the filter shapes the pulse-width-modulated output into a near-sinusoidal voltage, reducing dV/dt stress on insulation and limiting electromagnetic interference in automated machinery. Its design allows free installation inside a cabinet with forced convection, and surrounding air is the only cooling medium required to dissipate the thermal losses generated during continuous service.
The unit is classified as a sinusoidal filter, meaning its inductance and capacitance are tuned to deliver low-harmonic motor voltage at up to 3 × AC 480 V. Within that supply range, it carries a continuous phase current of 600 A, so it can be paired with high-power axes without saturation. The filter preserves motor torque control up to a fundamental frequency of 100 Hz, matching the speed range offered by most Rexroth inverters. To protect windings, its output never exceeds a crest value of 1000 V, and the rate of voltage change is limited to 1 kV/µs. Free-installation brackets simplify positioning, and natural airflow around the heat sinks maintains operating temperature when cabinet ventilation is present.
The electrical elements are sized for ambient conditions up to 60 °C; above this point, derating is required to prevent core saturation. During short production surges, the filter tolerates an overload of 150% for 60 s and a brief spike of 165% for 2 s, giving the drive time to clear acceleration peaks without tripping. Because the unit has an IP00 protection class, all live parts must be housed inside a grounded enclosure, especially when the installation site is at the permitted altitude of 3000 m, where air density drops and convective cooling efficiency falls.
Frequently Asked Questions about HMF01.1N-S0K1-M0600-N-480-NNNN:
Q: What cooling method is used for the HMF01.1N-S0K1-M0600-N-480-NNNN filter?
A: The HMF01.1N-S0K1-M0600-N-480-NNNN filter utilizes surrounding air for its cooling method.
Q: What is the rated current capacity of the HMF01.1N-S0K1-M0600-N-480-NNNN?
A: This filter is rated for a maximum current of 600 A, supporting high-power applications.
Q: What is the maximum output frequency of the HMF01.1N-S0K1-M0600-N-480-NNNN filter?
A: The HMF01.1N-S0K1-M0600-N-480-NNNN operates up to a max output frequency of 100 Hz.
Q: What is the peak overload capability of the HMF01.1N-S0K1-M0600-N-480-NNNN?
A: The filter supports a peak overload of 165% for 2 seconds to handle short-term load spikes.
Q: What are the maximum ambient temperature and installation altitude for the HMF01.1N-S0K1-M0600-N-480-NNNN?
A: It is designed for operation in environments up to 60 °C ambient temperature and up to 3000 m installation altitude.