HLL05.1F-04M0-S0475-N-11-01U2-NNNN Bosch Rexroth Indramat

Ask for Availability
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The HLL05.1F-04M0-S0475-N-11-01U2-NNNN is a Bosch Rexroth Indramat HLL bus choke rated for 475 A nominal current and DC 1100 V bus voltage. A nominal inductance of 4 mH and a 160 °C trigger temperature support stable DC bus conditioning and dependable thermal monitoring. A strong choice for high-current drive systems requiring consistent filtering performance.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HLL05.1F-04M0-S0475-N-11-01U2-NNNN is a water-cooled bus choke produced by Bosch Rexroth Indramat for the HLL Bus Chokes series. It is installed between the line rectifier and the drive inverter. In that position, the component smooths the DC link current, limits inrush peaks, and reduces high-frequency disturbances that can propagate through an automation plant’s common power bus. This helps keep shared power sections more stable during rapid load changes in multi-axis drive systems.

The choke carries a continuous load of 475 A while maintaining a DC link potential of 1100 V. Its windings present a nominal inductance of 4 mH, so the unit stores energy and filters current ripple at the switching frequencies used by servo inverters. The open-frame construction is designated IP00, which means all live parts must be installed inside a protected cabinet. Thermal sizing assumes a maximum ambient of 40 °C; above this value, the permissible current must be derated, and operation is limited when the enclosure temperature reaches 55 °C. A normally closed temperature switch embedded in the coil opens the N/C contact once the copper reaches 160 °C; its 1 A contact rating allows direct connection to the drive enable loop for rapid shutdown during an overtemperature fault.

Water circulation of 1.2 L/min through the integrated cooling channel removes resistive losses, and the circuit may be pressurized up to 4 bar without leakage. Coolant entering the choke must not exceed 60 °C to keep the core and insulation below the protection threshold, and the embedded switch trips at 160 °C if flow is interrupted. Installation should account for a shipping weight of 90 kg, and suitable lifting points should be provided so the device can be positioned securely on the panel floor without placing excess stress on adjacent busbars. The liquid-cooling layout also reduces reliance on surrounding cabinet airflow near the choke body.

Ambient Temp Derated
55 °C
Contact Form
N/C
Coolant Flow
1.2 l/min
Max Ambient Temp
40 °C
Max Operating Pressure
4 bar
Max Water Inlet Temp
60 °C
Nominal Current
475 A
Nominal Dc Bus Voltage
DC 1100 V
Nominal Inductance
4 mH
Protection Rating
IP00
Switch Capacity
1 A
Trigger Temperature
160 °C
Unpacked Weight
90 kg

Frequently Asked Questions about HLL05.1F-04M0-S0475-N-11-01U2-NNNN:

Q: What is the nominal DC bus voltage for the HLL05.1F-04M0-S0475-N-11-01U2-NNNN bus choke?

A: The HLL05.1F-04M0-S0475-N-11-01U2-NNNN can operate at a maximum DC bus voltage of 1100 V.

Q: What is the nominal current rating for the HLL05.1F-04M0-S0475-N-11-01U2-NNNN?

A: This model supports a nominal current of 475 A, making it suitable for high-current applications.

Q: What ambient temperature is specified for derated use of the HLL05.1F-04M0-S0475-N-11-01U2-NNNN?

A: The ambient temperature for derated operation is specified at 55 °C.

Q: What protection rating does the HLL05.1F-04M0-S0475-N-11-01U2-NNNN have?

A: Its protection rating is IP00, so it does not offer enclosure protection against dust or water.

Q: What is the required coolant flow rate for this HLL bus choke model?

A: The coolant flow required for operation is specified at 1.2 liters per minute.