4.94 based on 222 reviews

🙶 Excellent to work with and they stand behind their work. I would highly recommend them. 🙷

HLL05.1F-04M0-S0380-N-11-01U2-NNNN Bosch Rexroth Indramat

Ask for Availability
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The HLL05.1F-04M0-S0380-N-11-01U2-NNNN is a Bosch Rexroth Indramat HLL bus choke rated for 380 A continuous current with 4 mH inductance. Water-cooled design handles 580 W power dissipation and fits demanding 1100 V DC bus applications with dependable filtering behavior. A low 0.19 bar pressure drop at 6 l/min is a strong advantage for efficient thermal circuit integration.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HLL05.1F-04M0-S0380-N-11-01U2-NNNN is a liquid-cooled bus choke produced by Bosch Rexroth Indramat within the HLL Bus Chokes series. It is installed in the DC link of large inverter or drive packages to add inductance, attenuate ripple, and protect downstream components from current spikes. By moderating energy flow between rectifier and drive modules, the choke helps maintain stable operation of high-power industrial automation systems such as presses, extruders, and multi-axis motion lines.

The unit carries a continuous current of 380 A, allowing it to accompany multi-drive groups on a common DC bus. Its core inductance is 4 mH, which stores magnetic energy and smooths high-frequency components of the bus waveform. The device is designed for a nominal DC link voltage of 1100 V DC, matching the output of the associated rectifier stacks. Liquid cooling is provided through an internal channel with a filling capacity of 1.1 L, and proper operation requires a minimum coolant flow of 6 l/min, which produces a pressure drop of 0.19 bar across the circuit. The housing can tolerate a maximum operating pressure of 4 bar, and the inlet water temperature may reach 60 °C without affecting performance. Heat removed by the coolant keeps the winding temperature below the embedded thermal contact's actuation point.

The maximum ambient air temperature for this choke is 40 °C, and external derating is necessary above that value. An integrated normally closed temperature switch opens at 160 °C and is wired through contacts rated for 1 A at 250 V AC or 24 V DC, enabling the control system to shut down the drive if internal overheating occurs. Under rated coolant flow, the exchanger removes 580 W of thermal loss, which helps maintain electrical efficiency and reduce insulation stress. The magnetic assembly and cooling jacket weigh 33 kg, permitting rigid panel or frame mounting without additional structural reinforcement.

Continuous Current
380 A
Filling Capacity
1.1 l
Inductance
4 mH
Max Ambient Temp
40 °C
Max Operating Pressure
4 bar
Max Water Inlet Temp
60 °C
Minimum Flow Rate
6 l/min
Nominal Dc Bus
1100 V DC
Pressure Drop At 6 L/min
0.19 bar
Switch Capacity
1 A
Switching Voltage Ac
250 V AC
Switching Voltage Dc
24 V DC
Temp Contact Form
N/C
Temp Switch Trigger
160 °C
Water Power Dissipation
580 W
Weight
33 kg

Frequently Asked Questions about HLL05.1F-04M0-S0380-N-11-01U2-NNNN:

Q: What is the continuous current rating of the HLL05.1F-04M0-S0380-N-11-01U2-NNNN bus choke?

A: The HLL05.1F-04M0-S0380-N-11-01U2-NNNN can handle a continuous current of 380 A for DC bus filtering applications.

Q: What is the inductance value of the HLL05.1F-04M0-S0380-N-11-01U2-NNNN?

A: This model features an inductance rating of 4 mH to support efficient smoothing of DC currents.

Q: What is the maximum operating pressure supported by the HLL05.1F-04M0-S0380-N-11-01U2-NNNN?

A: The maximum operating pressure for this bus choke is specified at 4 bar.

Q: What is the maximum allowable water inlet temperature for the HLL05.1F-04M0-S0380-N-11-01U2-NNNN?

A: The water inlet temperature should not exceed 60 °C for this unit.

Q: What is the nominal DC bus voltage for the HLL05.1F-04M0-S0380-N-11-01U2-NNNN?

A: This bus choke is designed for a nominal DC bus voltage of 1100 V DC.