HDS02.2-W040N

  • Rated 4.5 (31 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
  • MPN: R911284804
  • Stock: In-Stock, Ships Today
  • Factory New Pricing Available!
    Request a Quote!
  • Call for Expedited Shipping and Product Condition Options
The HDS02.2-W040N Servo Controller is manufactured by Rexroth Indramat Bosch. This controller is cooled by an Internal Blower, and has a rated current of 40A. This HDS controller is not equipped with Command Communication and the Controller Family is DIAX04.

Request a Quote Request Repair

Standard Repair Time is 1 - 2 weeks. 4 Day Rush Repair options are available.

✓ In-Stock!

HDS02.2-W040N

  • Rated 4.5 (31 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
  • MPN: R911284804
  • Stock: In-Stock, Ships Today
  • Factory New Pricing Available!
    Request a Quote!
  • Call for Expedited Shipping and Product Condition Options
The HDS02.2-W040N Servo Controller is manufactured by Rexroth Indramat Bosch. This controller is cooled by an Internal Blower, and has a rated current of 40A. This HDS controller is not equipped with Command Communication and the Controller Family is DIAX04.

Request a Quote Request Repair

Standard Repair Time is 1 - 2 weeks. 4 Day Rush Repair options are available.

Warranty
1 Year Wake Industrial Warranty Included
Shipping
Worldwide shipping via DHL, UPS, and Fedex
Repairs
Sell Us Your Surplus
Have a HDS02.2-W040N to sell?
To Speak to a sales representative for pricing and lead time:

Product Description

The HDS02.2-W040N HDS series drive controller belongs to the DIAX04 product group. The drive controller has a line code of 2 and a version code of 2. It can be used with the MKD, MHD and 2AD series of AC motors from the manufacturer for controlling and monitoring them. The product acts as a rapid-response drive. The device can be utilized in robotics and machine tools. The unit must be connected to an HVR or an HVE supply module that provides the power and signal voltages required by the controller. It may be required to install an additional HZB brake resistor if the performance is high and the power supply is not able to support regeneration. This resistor controls the generated energy due to breaking action.

The drive controller has a peak current and a rated current of 40A. The product features a Class C insulation as per DIN VDE 0110 specifications. The device must be installed and used only after reading the documentation provided. It should be installed only in commercial machinery. The unit must be operated only if the application that it is used for is in compliance with the required national EMC regulations. The controller should not be operated even for a brief period if there is no permanent connection of the ground wire. It is intended to be operated between 5°C and 45°C.

The product has a leakage current of 3.5mA. The device may have high electric voltage if its connections are done incorrectly. The unit must be allowed to cool down for at least 10 minutes before touching it. It should neither be mounted nor installed in a damaged or malfunctioning state. The drive controller can be used in both multiple-axis and single-axis control and drive applications. The product features a modular structure. The HDS02.2-W040N controller has a one-year warranty and can be sent to the address of your preference.

HDS02.2-W040N Documents

  • HDS022W040N
  • HDS02 2 W040N
  • hds02.2-w040n
  • HDS2.2-W040N

HDS02.2-W040N Technical Specifications

Command Communication: Not Equipped
Insulation classification: C according to DIN VDE 0110
cooling: Internal air blower
Rated current: 40A
Controller family: DIAX04
Peak current: 40A
Weight: 6.5kg
Continuous current at 4kHz/8kHz: 20/15A
Power Loss with continuous current: 125W
Power consumption for signal processing: 20W

Frequently Asked Questions about HDS02.2-W040N


Q: How can the HDS02.2-W040N be adapted to specific industrial application?

A: The HDS02.2-W040N features a sophiaticated modular design. The controller can adapted to a respective function through the use of additional modules which can be inserted into the controller housing.

Q: How sensitive is the HDS02.2-W040N to electrostatic loads?

A: The HDS02.2-W040N drive controller is very sensitive to electrostatic loads. All objects coming in contact with the controller must be properly discharged by means of grounding.

Q: Is it necessary for customers to carry out high-voltage and insulation check on the HDS02.2-W040N after delivery?

A: The HDS02.2-W040N has already passed through high-voltage and insulation checks before it is delivered to operators. Customers should avoid carrying out these tests again to avoid damaging the controller.

Q: What is the X2 serial interface on the HDS02.2-W040N used for?

A: The serial interface on the HDS02.2-W040N controller is designed to support the communication of the controller with PC. The serial interface is generally used for programming, parameterization, and diagnoses upon commissioning and during service.

Q: What is the starting lockout on the HDS02.2-W040N controller designed for?

A: The starting lockout is a safety mechanism on the HDS02.2-W040N that is used to secure against unintentional startus of motors connected to the drive controller in case an error occurs. It serves to ssecurely switch off separate working areas within the servo system.