HCS03.1E-W0100-A-05-NPBV-AA
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911331171
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The HCS03.1E-W0100-A-05-NPBV-AA IndraDrive Controller boasts a rated power output of 10 kW, a maximum output current of 23 A, and a cooling method utilizing internal air. Part of the HCS IndraDrive Controllers from Bosch Rexroth Indramat, it features Profibus fieldbus options and a compact book size enclosure for control cabinet mounting.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS03.1E-W0100-A-05-NPBV-AA is a Bosch HCS series drive controller. It is designed and manufactured for the purpose of industrial motor control. It has two main components: one of these is a power section and the second one is a control section. The power section interfaces with the AC mains, converting AC input to DC for the control section and other controller components that run on DC power. The control section contains hardware that runs control system software tasked with monitoring and controlling Bosch servo motors. An internal blower on the HCS03.1E-W0100-A-05-NPBV-AA controller provides cooling. The controller features a bottom-mounted cool air inlet and a top-mounted hot air outlet for efficient airflow management. The blower forces cool air over controller components. The top site can get very hot due to the exiting warm air.
Therefore, operators must provide sufficient free space near the top of the controller. This is particularly crucial in the event of an internal blower failure or any other issue causing excessive ambient temperature rise. The HCS03.1E-W0100-A-05-NPBV-AA controller supports connection to a three-phase AC power input. Connection to single-phase AC system is not permitted. The allowable input voltage range is 400 to 500 volts at a frequency of 50 to 60 hertz, with a maximum current rating of 100 Amps. Its housing belongs to IP20 protection class. With this ingress protection rating, the controller can be deployed outdoors when it is mounted inside an appropriate control cabinet. Depth of the controller is 262 millimeters, which increases to 315 millimeters due to the connectors and cabling at the back. The controller’s height is 490 millimeters, and its width is approximately 225 millimeters. Weight of the control section is 0.4 kilograms, while the assembled controller has a total weight of 20 kilograms.
Frequently Asked Questions about HCS03.1E-W0100-A-05-NPBV-AA:
Q: What is the upper voltage limit for the DC bus?
A: The upper voltage limit for the DC bus is 900 Volts.
Q: What is the lower voltage limit for the DC bus?
A: The lower voltage limit for the DC bus is 400 Volts.
Q: What is the mains frequency range?
A: The mains frequency range is 50 to 60 Hertz.
Q: Can the drive controller be connected to single-phase AC input?
A: Connection of the drive controller to single-phase AC input is not permitted.
Q: How can you identify the controller?
A: Type plates attached to controller components allow easy identification.