The HCS02.1E-W0070-A-03-LNNN-AA drive controller delivers a rated power output of 7 kW, operates on 380-480 V AC 3-phase input, and features IP20 protection with wall mounting. Part of the HCS IndraDrive Controllers series by Bosch Rexroth Indramat, it supports Ethernet-based communication interfaces and utilizes internal air cooling.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
Manufactured by Bosch Rexroth Indramat, this HCS02.1E-W0070-A-03-LNNN-AA drive controller incorporates a maximum braking current of 2 A. The controller’s control voltage must be supplied by an external power supply. This product is connected with other controllers or additional components with a DC bus connection. The device’s housing should be grounded by connecting its bare metal rear panel in conductive form to the mounting surface inside the control cabinet. This unit’s outlet temperature at its top must be within the specified limits. Its power connection should be isolated using a safety-related starting lockout to prevent unintentional start during maintenance. The controller’s HAS accessories kit contains the components needed for its mounting and installation.
This product uses its control voltages for its power and control section and brake control. The device’s control panel contains a display and keys below it to assist in its operation. This unit needs a power supply disconnection during maintenance or when it is stored for a long time. Its application-specific parameters are stored in a volatile memory. The controller-related operating status and warning and error messages are displayed on the control panel. This product works with third-party rotary and linear asynchronous or synchronous motors. The device’s use is permitted only under the specified ambient and installation conditions. This unit is suitable only for the safety-relevant applications approved by the manufacturer. Its cooling is mandatory before undertaking maintenance work.
The drive controller’s electrical parts may have a voltage of more than 50 V soon after and during use. This product uses a copper wire with at least 10 mm² cross-section for its equipment grounding connection. The device has touch guards for connections with voltages from 5 V to 50 V. This unit is never meant to be operated near high-frequency, radio, and remote control equipment. It delivers high performance.
Frequently Asked Questions about HCS02.1E-W0070-A-03-LNNN-AA:
Q: What kind of inputs are the probe inputs of the HCS02.1E-W0070-A-03-LNNN-AA controller?
A: The probe inputs of the HCS02.1E-W0070-A-03-LNNN-AA controller are rapid digital inputs.
Q: What sensor should a third-party motor used with the HCS02.1E-W0070-A-03-LNNN-AA controller have?
A: A third-party motor used with the HCS02.1E-W0070-A-03-LNNN-AA controller should have a temperature sensor.
Q: Why should low batteries of the HCS02.1E-W0070-A-03-LNNN-AA controller not be reactivated?
A: Low batteries of the HCS02.1E-W0070-A-03-LNNN-AA controller should not be reactivated as they may explode.
Q: What precaution should be taken during the transport and storage of the HCS02.1E-W0070-A-03-LNNN-AA controller?
A: The HCS02.1E-W0070-A-03-LNNN-AA controller should be free of moisture condensation and ice during transport and storage.
Q: What should be done when the HCS02.1E-W0070-A-03-LNNN-AA controller is stored for a long period?
A: When the HCS02.1E-W0070-A-03-LNNN-AA controller is stored for a long period, it should be operated for an hour once a year with the mains voltage.