4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

HCS01.1E-W0028-A-03-B-ET-EC-EC-S5-NN-NW Bosch Rexroth Indramat

MPN: R911387220

No Tariffs On US Orders
  • Rated 4.4 (45 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0028-A-03-B-ET-EC-EC-S5-NN-NW is part of the HCS IndraDrive Controllers series. This drive controller has a MultiEthernet communication interface and supports encoder interfaces IndraDyn Hiperface and EnDat 2.1/2.2. It features an internal air cooling system with an integrated blower and has a device peak current of 28 Amps.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0028-A-03-B-ET-EC-EC-S5-NN-NW is a drive controller manufactured by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It functions as the power and control core for a single servo axis, converting the plant’s three-phase supply into regulated motor current while exchanging high-speed position data with the connected encoder. This places the unit in closed-loop motion tasks such as pick-and-place stations, packaging lines, and metal-cutting equipment. That operating role lets the drive respond quickly to command changes while maintaining stable feedback processing during repetitive machine cycles.

The controller accepts a mains window of 3 × AC 200…500 V ±10%, allowing installation on industrial networks with varying supply levels. A device peak current of 28 A sets the short-term current available during rapid acceleration or temporary load changes. Network connectivity is provided through a MultiEthernet interface, so one port can support several Ethernet-based fieldbus options without additional hardware. The control section uses the BASIC variant, which covers standard motion functions for routine axis operation. An IP20 housing protects live parts from accidental contact and indicates that the unit is intended for installation inside a cabinet where airflow and filtration are managed.

Cooling is provided by internal air cooling through an integrated blower, which pulls cabinet air through the heat sink and removes heat without external ducting. Both feedback sockets support Hiperface/EnDat 2.1/2.2 protocols, so absolute position data can be transferred on a bidirectional serial channel that simplifies wiring. The power stage is configured for infeeding and fed operation, allowing several drives to share a common DC bus supplied by one rectifier and improving energy use during regenerative braking. The unit is Design Version 1, which indicates the earliest production design with fixed mechanical dimensions and connector layout.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
28 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0028A03BETECECS5NNNW
  • HCS01 1E W0028 A 03 B ET EC EC S5 NN NW
  • hcs01.1e-w0018-a-03-e-s3-ec-nn-l4-nn-fw
  • HCS1.1E-W0028-A-03-B-ET-EC-EC-S5-NN-NW

Frequently Asked Questions about HCS01.1E-W0028-A-03-B-ET-EC-EC-S5-NN-NW:

Q: What communication interface does the HCS01.1E-W0028-A-03-B-ET-EC-EC-S5-NN-NW drive controller use?

A: This model features MultiEthernet communication, supporting a range of industrial Ethernet protocols.

Q: What is the maximum peak current output of the HCS01.1E-W0028-A-03-B-ET-EC-EC-S5-NN-NW?

A: The peak device current for this controller is 28 A.

Q: Which cooling method is employed on this HCS IndraDrive controller?

A: The HCS01.1E-W0028-A-03-B-ET-EC-EC-S5-NN-NW uses internal air cooling with an integrated blower.

Q: Which encoder interface types are provided with this model?

A: Both encoder interfaces support IndraDyn Hiperface and EnDat 2.1/2.2 feedback devices.

Q: What mains voltage range does the HCS01.1E-W0028-A-03-B-ET-EC-EC-S5-NN-NW support?

A: This controller is designed to operate at mains voltages of 3 x AC 200 to 500 V with a ±10% tolerance.


Internal Product Review

  • ‘‘The HCS01.1E-W0028-A-03-B-ET-EC-EC-S5-NN-NW is an HCS IndraDrive Controller from Bosch Rexroth Indramat, featuring MultiEthernet communication and a BASIC control section. Its integrated internal air blower provides effective cooling, and it delivers a peak current of 28 A for demanding automation tasks. The IP20 rating supports safe installation in protected environments, making this drive controller a dependable choice for advanced motion control applications.’’