4.95 based on 202 reviews

🙶 Product was as advertised, got the machine back up and running at a fraction of OEM price. Delivered on ti... 🙷

HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-NW Bosch Rexroth Indramat

MPN: R911374554

No Tariffs On US Orders
  • Rated 4.6 (23 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Current response time:
3 Minutes 29 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-NW is a drive controller from the HCS IndraDrive Controllers series. It has a device peak current of 18 Amps and supports MultiEthernet communication. The unit features an internal air cooling method using an integrated blower and an IP20 rating. It is designed for use with 3-phase AC mains voltage from 200 to 500 Volts.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-NW is a drive controller manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. Installed between the plant power bus and an IndraDyn servo motor, it converts incoming three-phase energy into regulated output that manages torque, speed, and position loops in automated handling, packaging, and light machining stations where coordinated axis control is required. This controller accepts a mains window of 3 × AC 200–500 V ±10%, allowing operation on both low- and medium-voltage factory grids without tap changes.

During dynamic acceleration, the power stage can deliver a device peak current of 18 A, which is the highest motor current available before the drive’s electronic protection limits engage. Cabinet placement is simplified by an IP20 housing that guards against accidental contact with live parts while relying on the enclosure for added dust protection inside the cabinet. Thermal management is handled by integrated blower cooling, and the internal fan pulls air through the heat sink without external ducting. For network integration, the unit provides a MultiEthernet interface, allowing communication over EtherNet/IP, PROFINET, EtherCAT, or standard TCP/IP through the same port.

The power electronics are paired with a control section in the BASIC design class, supplying core motion functions for standard servo applications without optional safety or advanced technology packages. The assembly is design version 1, so its parameters and mechanical dimensions follow the first release of the HCS01 line. Feedback from the motor arrives through the primary Encoder IndraDyn Hiperface/EnDat 2.1/2.2 port, enabling high-resolution position control, while the secondary encoder slot and dedicated safety interface are left unpopulated to simplify wiring. DC bus energy is managed through infeeding and fed operation, allowing several drives to share regenerated power across a common bus during braking and deceleration.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0018A03BETECNNNNNNNW
  • HCS01 1E W0018 A 03 B ET EC NN NN NN NW
  • hcs01.1e-w0018-a-03-a-cc-ec-et-sb-nn-fw
  • HCS1.1E-W0018-A-03-B-ET-EC-NN-NN-NN-NW

Frequently Asked Questions about HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-NW:

Q: What type of communication interface is provided on the HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-NW controller?

A: This controller supports MultiEthernet for versatile network integration with various industrial protocols.

Q: How is the HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-NW controller cooled?

A: The HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-NW features an integrated blower for internal air cooling.

Q: What is the peak current supported by the HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-NW controller?

A: The device supports a peak current of 18 A for demanding operational cycles.

Q: What mains voltage range does the HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-NW controller support?

A: This model operates with a 3-phase AC mains voltage ranging from 200 to 500 V, with a tolerance of ±10%.

Q: Which encoder interfaces are supported by the HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-NW controller?

A: The primary encoder interface is compatible with IndraDyn Hiperface and EnDat 2.1/2.2 encoders.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-NW is an HCS drive controller with MultiEthernet communication and a BASIC control section. Internal air cooling supports stable thermal management, and the 18 A peak current gives the unit strong drive capability for demanding motion applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo