4.95 based on 202 reviews

🙶 Product was as advertised, got the machine back up and running at a fraction of OEM price. Delivered on ti... 🙷

HCS01.1E-W0018-A-03-B-ET-EC-EM-S4-NN-FW Bosch Rexroth Indramat

MPN: R911345158

No Tariffs On US Orders
  • Rated 4.6 (54 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 1-2 Days

Current response time:
3 Minutes 36 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-EM-S4-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features MultiEthernet communication and supports encoder feedback through IndraDyn Hiperface or EnDat 2.1/2.2, as well as encoder emulation. This controller uses an internal air cooling system and operates at a peak current of 18 Amps with an IP20 rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

Bosch Rexroth Indramat's HCS01.1E-W0018-A-03-B-ET-EC-EM-S4-NN-FW is part of the HCS IndraDrive Controllers series. This HCS Drive Controller converts line power into regulated DC and switching waveforms for synchronous or induction motors, enabling position and velocity loops within automated packaging machines, transfer lines, and assembly cells. The unit follows the HCS01 mechanical outline and is identified as design version 1, so it fits standard 45 mm frame widths and matches the wiring accessories used for that line. Its role is to act as the axis inverter that partners with a separate control section to close motion loops.

The power stage accepts a three-phase supply of 3 × AC 200…500 V ±10% and internally rectifies and buffers that energy. When load surges occur, it can deliver up to 18 A of device peak current without tripping, which covers short acceleration peaks on medium-inertia drives. Thermal management relies on internal air cooling through an integrated blower, so no external ducting is required. Protection against accidental contact is classified as IP20, which is suitable for installation inside a closed electrical cabinet. Network traffic for configuration and real-time commands is handled over MultiEthernet, allowing the same hardware to join EtherNet/IP, PROFINET, or EtherCAT fieldbuses without option cards.

For feedback and higher-level logic, the controller is paired with a BASIC control section, as indicated in the type code and pairing note. Rotor position can be read directly through the high-resolution Encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface, while legacy systems may be served by the selectable encoder emulation port. The DC bus is supplied and regenerated by an infeeding and regenerative power module, making the unit suitable for multi-axis common-bus installations. No additional design options are included beyond the baseline functions.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder emulation
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0018A03BETECEMS4NNFW
  • HCS01 1E W0018 A 03 B ET EC EM S4 NN FW
  • hcs01.1e-w0018-a-02-e-s3-ec-nn-nn-nn-fw
  • HCS1.1E-W0018-A-03-B-ET-EC-EM-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-03-B-ET-EC-EM-S4-NN-FW:

Q: What is the peak current supported by the HCS01.1E-W0018-A-03-B-ET-EC-EM-S4-NN-FW controller?

A: The HCS01.1E-W0018-A-03-B-ET-EC-EM-S4-NN-FW provides a peak current of 18 A, allowing for short bursts of high power during demanding operations.

Q: What type of communication interface is available on the HCS01.1E-W0018-A-03-B-ET-EC-EM-S4-NN-FW?

A: This controller features a MultiEthernet communication interface, supporting multiple industrial Ethernet protocols for flexible connectivity.

Q: How is the HCS01.1E-W0018-A-03-B-ET-EC-EM-S4-NN-FW drive controller cooled?

A: Cooling is handled internally via an integrated blower, providing efficient air cooling for the unit.

Q: What encoder interfaces are included with the HCS01.1E-W0018-A-03-B-ET-EC-EM-S4-NN-FW?

A: The controller is equipped with both IndraDyn Hiperface/EnDat encoder input and encoder emulation output interfaces for versatile feedback options.

Q: What is the IP rating of the HCS01.1E-W0018-A-03-B-ET-EC-EM-S4-NN-FW drive controller?

A: The HCS01.1E-W0018-A-03-B-ET-EC-EM-S4-NN-FW has an IP20 rating, meaning it offers protection against solid objects but is not rated for water resistance.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-03-B-ET-EC-EM-S4-NN-FW is an HCS drive controller featuring MultiEthernet communication and a BASIC control section design. Internal blower cooling and IP20 protection give the unit a clean, practical configuration for enclosed industrial panels. An 18 A peak current rating makes the controller a strong option for responsive motion applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo