HCQ02.1E-W0025-A-03-B-L8-1S-D1-D1-NN-PW Bosch Rexroth Indramat
MPN: R911372642
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
6 Minutes
12 Seconds
The Bosch Rexroth Indramat HCQ02.1E-W0025-A-03-B-L8-1S-D1-D1-NN-PW is part of the HCQ Micro Controls series and offers a rated power of 25 kW with a rated input current of 44 Amps. This micro control unit features 32 digital inputs, 16 digital outputs, and five encoder interfaces. It operates with a mains connection voltage of 3 x AC 200 to 500 V and includes SERCOS III master communication.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
Bosch Rexroth Indramat manufactures the HCQ02.1E-W0025-A-03-B-L8-1S-D1-D1-NN-PW within the HCQ Micro Controls series and the broader HCQ Micro Control product group. Serving as a feeding power supply and micro control, the device combines high-density I/O processing with drive coordination for mid-power machinery. Its embedded PC based on an LX 800 processor and a Basic control section allow user programs and real-time motion tasks to execute in the same enclosure, simplifying cabinet layouts in automated assembly lines and packaging equipment.
In electrical terms, the unit delivers a rated output of 25 kW while accepting three-phase mains in the range of 3 x AC 200...500 V with a ±10 % tolerance. Under those conditions it draws a continuous line current of 44.0 A at an input frequency of 50...60 Hz. Branch protection is achieved with a 60 A; class J fuse, and the assembly is UL evaluated for a 42 kA rms short-circuit rating. Internally, a blower forces cooling air across the power stages, and the feeding topology regenerates DC for the drive bus while supplying an output of 3 x AC 0...500 V to downstream inverters. Line code 02 and design version 1 distinguish firmware alignment within the HCQ platform.
Installation details center on protection level IP 20, a mass of 11.70 kg, and a compact frame measuring 320 mm wide, 191 mm deep, and 455 mm high. The controller offers 32 digital inputs, 16 digital outputs, five encoder links, and four probe interfaces, giving motion axes precise position and trigger data without external I/O blocks. A built-in SERCOS III master provides deterministic fieldbus access, and the LX 800 embedded PC manages higher-level communication. Dual DEA40.1 option slots are populated for application-specific expansion, and no alternate design variants are declared, streamlining stocking and service routines.
Frequently Asked Questions about HCQ02.1E-W0025-A-03-B-L8-1S-D1-D1-NN-PW:
Q: How many digital inputs and outputs does the HCQ02.1E-W0025-A-03-B-L8-1S-D1-D1-NN-PW micro control unit offer?
A: The HCQ02.1E-W0025-A-03-B-L8-1S-D1-D1-NN-PW is equipped with 32 digital inputs and 16 digital outputs.
Q: What is the rated input current for the HCQ02.1E-W0025-A-03-B-L8-1S-D1-D1-NN-PW?
A: This model operates with a rated input current of 44.0 A as per UL standards.
Q: What type of branch circuit protection fuse is used in the HCQ02.1E-W0025-A-03-B-L8-1S-D1-D1-NN-PW?
A: The power circuit in this device is protected by a 60 A class J branch circuit protection fuse.
Q: What is the degree of protection on the HCQ02.1E-W0025-A-03-B-L8-1S-D1-D1-NN-PW control unit?
A: The degree of protection is rated at IP 20, providing basic protection against solid objects.
Q: How is the HCQ02.1E-W0025-A-03-B-L8-1S-D1-D1-NN-PW cooled during operation?
A: Cooling is handled internally through an integrated blower using air.