DKCXX.3-040-7-FW Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat DKCXX.3-040-7-FW is part of the DKC Drive Controllers series and is classified as an EcoDrive product. It features a rated current of 40 Amps and a DC-bus nominal voltage of 700 Volts. The controller has a maximum output voltage of 800 Volts and supports output frequencies up to 1000 Hz, while weighing 5.7 kilograms.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The DKCXX.3-040-7-FW is an EcoDrive servo drive controller manufactured by Bosch Rexroth Indramat for the DKC Drive Controllers series. It regulates power from a shared DC bus to a connected motor, enabling position and velocity control in automated machinery. By converting the internal link voltage to a commanded three-phase output, this controller forms the electronic interface between the motion program and the mechanical axis. That arrangement helps centralize power conversion while allowing each connected axis to receive independent current and motion control.
The unit draws 21 W for its control electronics while the logic circuits are energized by a 24 VDC auxiliary supply. Internally the DC bus is held at 700 V, and the power stage is rated for a continuous output of 40 A. The auxiliary supply keeps command processing and monitoring functions active while the main power section is managed through the shared bus. The inverter can modulate its PWM pattern up to 1000 Hz, producing line-to-line voltages as high as 800 V at the terminals. Continuous thermal losses are limited to 180 W, so cabinet ventilation must dissipate this heat during sustained operation. A maximum input current of 16 A and a short-circuit current rating of 42 kA RMS support use on properly protected industrial feeders.
Design 3 uses a narrow housing that is only 65 mm wide, while the full assembly remains 360 mm tall and 261 mm deep. The unit weighs 5.7 kg, which helps support dense side-by-side mounting in multi-axis racks. It operates at ambient temperatures up to 45 °C at nominal current and can remain in service up to 55 °C with derated output. Airflow clearances of 80 mm below and 150 mm above the heat sink must be maintained so heat can escape without restriction. Adequate spacing is important when the drive is mounted on DIN rails or panels because blocked airflow can reduce available current. The enclosure and upstream protection must be selected for an interrupt capacity of 42000 A RMS so faults can be cleared without damaging the power stage.
Frequently Asked Questions about DKCXX.3-040-7-FW:
Q: What is the maximum output frequency of the DKCXX.3-040-7-FW drive controller?
A: The DKCXX.3-040-7-FW has a maximum output frequency of 1000 Hz, supporting high-speed motor operation.
Q: What is the DC-bus nominal voltage specification for the DKCXX.3-040-7-FW?
A: This drive controller supports a DC-bus nominal voltage of 700 V.
Q: What is the maximum input current for the DKCXX.3-040-7-FW?
A: The maximum input current for this model is 16 A.
Q: What is the rated current capacity of the DKCXX.3-040-7-FW?
A: The DKCXX.3-040-7-FW is rated for a current of 40 A.
Q: How much power dissipation occurs in DKCXX.3-040-7-FW during continuous operation?
A: This controller has a power dissipation of 180 W during continuous operation.