KL8001-0000 Beckhoff
Wake Industrial LLC is not an authorized distributor of this product.
The Beckhoff KL8001-0000 is part of the KL Analog Input Modules series and features IP20 protection class. It supports up to 10 contactors per bus coupler and provides mains to k-bus isolation rated at 6000 V. The module handles a maximum power path current loading of 25 A and delivers accuracy ratings of 0.15 Arms for current, 2 Vrms for voltage, 5 W for power, and 1 kWh for energy measurements.
Internal Product Review
The KL8001-0000 is a Beckhoff analog input module suited for dependable electrical monitoring in industrial control systems. IP20 protection and 6000 V mains/K-bus isolation give the module a strong safety profile for cabinet integration. Current accuracy of 0.15 Arms and power accuracy of 5 W make the module a very capable choice for precise measurement tasks.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KL8001-0000 is an analog input module produced by Beckhoff within the KL Analog Input Modules series. It is installed on a Bus Coupler rail to capture electrical measurements from up to ten contactor-fed branches and forward those values to the higher-level controller over the K-bus. In industrial automation, the unit is used for onboard power monitoring, enabling PLC logic to react to load changes, detect faults, and record consumption profiles without separate transducers.
The module’s power path can conduct up to 25 A, letting it handle sizable motor or heater feeders before the measurement circuit saturates. Galvanic separation between the mains terminals and the internal communication bus is rated at 6000 V, which protects the control electronics from line disturbances. During continuous sampling, the device achieves a current accuracy of 0.15 Arms; combined with a voltage accuracy of 2 Vrms, this supports meaningful phase power calculations. The process image contribution is 96 bits I/O, so the controller receives compact status, diagnostic, and value data every scan. Two ten-pin flat plug sockets form the K-bus connection, simplifying module stacking without extra wiring, and the measuring voltage is limited to 500 V.
When abnormal conditions occur, the power stage endures fault currents up to 5000 A, allowing upstream protection devices time to trip before the PCB traces fail. The copper path exhibits a resistance of < 1 mΩ, minimizing thermal rise and measurement drop across the shunt. The housing is rated IP20, which restricts finger access and the entry of foreign objects in typical cabinet environments. For consumption logging, the energy channel resolves increments down to 1 kWh, and the power channel maintains a nominal accuracy of 5 W; together, these figures support load profiling and long-term energy tracking without external meters.