KL3314-0024

    In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The KL3314-0024, an analog input module with four inputs, supports a power supply via the K-bus and thermocouple sensor types J, K, L, B, E, N, R, S, T, U. Manufactured by Beckhoff, it's part of the KL Analog Input Series, offering a 0.1°C per digit resolution. The module weighs approximately 75 g for reliability.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The Beckhoff component identified as KL3314-0024 is a 4-channel analog input terminal specifically designed for temperature measurement using thermos-couples. Beckhoff is well-known for its focused and unique industrial automation technologies that offer high levels of preciseness and performance worldwide.

The KL3314-0024 terminal bus supports multiple forms of thermos-couple types with also a type K. It also measures variable temperature within limited ranges on the thermocouple type K. It also works by using milli-volt calculations within a wide range of positive and negative 30 mV -120 mV. It works with a 2-wire connection method and it provides useful results and operates with a conversion time of about 250 milliseconds. The terminal's precision is remarkable as it helps by offering 0.1°C per digit resolution and maintains measurement error of just ±0.5% for the full scale. This KL analog series bus terminal includes a wiring failure indication and features electrical isolation of up to 500V between the K-bus and signal voltage for adding safety. It has a small maintenance requirement and works with proper temperature range that is specified by the manufacturer.

This KL3314-0024 terminal bus is a compact and efficient design that measures just 12 mm of height with 100 mm width having 68 mm length with a mass of only 75 grams. This helps in making it easy to install on standard 35 mm DIN rails as per standard. It is built to function in a challenging industrial setup by operating reliably in temperatures between 0°C and 55°C and capable of being stored at temperatures down to -25°C. It consumes only 75 mA from the K-bus without requiring any power contacts for its operation. It has a built-in resistance to vibration with shock and it also meets IP20 protection.

Connection method
2-wire
Conversion time
~250 ms
Current consumption (K-bus)
typ. 75 mA
EMC standard
EN 61000-6-2/6-4
Measurement error
<±0.5% FS
mV measurement range
±30…±120 mV
Number of inputs
4
Operating temperature
0…+55°C
Power supply
via K-bus
Process image control/status width
4 × 8 bit (optional)
Process image data width
4 × 16 bit
Resolution
0.1°C
Sensor types
TC J, K, L, B, E, N, R, S, T, U; mV inputs
Storage temperature
-25…+85°C
Temperature range (Type K)
-100…+1370°C
Vibration/shock standard
EN 60068-2-6/2-27
Weight
approx. 75 g
Wiring failure indication
Yes

Frequently Asked Questions about KL3314-0024:

Q: What thermocouple types are compatible with the KL3314-0024?

A: The KL3314-0024 works with a variety of thermocouple types, including J, K, L, B, E, N, R, S, T, and U. By default, the terminal is set to type K but can be configured for other types as needed.

Q: What connection method is used by the KL3314-0024?

A: The KL3314-0024 utilizes a 2-wire connection method for connecting thermocouples. This simplifies installation and ensures a reliable signal transmission from the sensor to the terminal.

Q: Does the KL3314-0024 provide any safety features?

A: Yes, the KL3314-0024 includes built-in wiring failure detection. This feature enhances system diagnostics by alerting users of potential wiring issues ensuring reliable operation.

Q: How does the KL3314-0024 enhance system diagnostics?

A: The KL3314-0024 features a built-in wiring failure indication, which alerts the system in case of wiring issues. This improves system diagnostics and helps avoid downtime.

Q: Can the KL3314-0024 be used in hazardous or extreme environments?

A: The KL3314-0024 is designed for standard industrial environments with a temperature range of 0°C to 55°C. For extreme or hazardous environments, additional protective measures or devices may be required.


Internal Product Review

  • ‘‘The KL3314-0024 from KL analog input series of Beckhoff delivers durable and accurate temperature thermocouple applications across four channels making it ideal for industries. Its 16-bit resolution and high precision works with control systems. Users appreciate its well-performance and ease of installation by boosting efficiency.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo