4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

KL3314 Beckhoff

In-Stock, Ships 3-5 Days
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The KL3314 is a Beckhoff analog input module with 4 inputs and internal cold junction compensation. Support for 2-wire connection and open-circuit recognition gives the module dependable signal handling in temperature measurement circuits. Resolution of 0.1 °C/digit and measuring error below ±0.5% FS support precise thermal monitoring.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KL3314 is an analog thermocouple input terminal produced by Beckhoff for the KL Analog Input Modules series. The unit samples low-level millivolt signals from temperature sensors and places the converted data on the system bus, allowing a PLC to monitor process temperatures in real time. Installed alongside other KL terminals, it serves as a compact temperature acquisition node inside an industrial automation cabinet. Its direct integration with the terminal system reduces the need for separate signal-conditioning equipment between the sensors and the controller.

It provides 4 inputs, each independently digitized with a resolution of 0.1 °C per digit, so small temperature changes are visible to the controller. The default conversion cycle of 250 ms determines how often each channel is updated; this rate suits slow to medium thermal processes where rapid oversampling is unnecessary. To maintain accuracy, internal cold-junction compensation accounts for the temperature at the terminal connection point, and the computed result is delivered as a 0.1 °C two’s-complement value. Channel data occupy 8 bytes in the fieldbus process image, simplifying mapping within PLC memory. The basic measuring error is limited to ±0.5% FS, which restricts the maximum deviation across the full measuring range. Galvanic separation rated at 500 V protects upstream logic from differences in ground potential. The terminal also supports direct millivolt measurement, extending its use beyond standard thermocouple applications.

For physical integration, the housing clips onto a 35 mm DIN rail and exposes eight terminal points for a 2-wire connection, reducing the amount of sensor cabling required. The internal circuitry monitors lead integrity, and open-circuit recognition immediately reports a fault if a sensor line is interrupted. Communication over the K-bus uses 4 × 16 bits, providing a structured data interface for compatible Beckhoff bus couplers and controllers. The enclosure has an IP20 protection rating, so the module must be installed inside a suitable cabinet that protects it from conductive dust, liquid spray, and accidental contact. Its narrow terminal-style housing allows multiple temperature channels to be installed without occupying the panel space required by larger standalone transmitters.

Cold Junction Compensation
Internal
Connection Technology
2-wire
Default Conversion Time
250 ms
Default Output Format
0.1 °C Two's Complement
Input Data Length
8 bytes
Isolation Voltage
500 V
K-bus Input Width
4 x 16 bits
Measuring Error
<±0.5% FS
Mounting Rail
35 mm DIN rail
Mv Measurement
Supported
Number of Inputs
4
Open-circuit Recognition
Yes
Protection Class
IP20
Resolution
0.1 °C/digit
Terminal Points
8

Frequently Asked Questions about KL3314:

Q: How many analog inputs are provided on the KL3314 module?

A: The KL3314 supports 4 separate analog input channels.

Q: What type of cold junction compensation is used in the KL3314?

A: This module uses internal cold junction compensation for temperature accuracy.

Q: What is the measurement resolution of the KL3314 analog input module?

A: The KL3314 offers a resolution of 0.1 °C per digit in temperature measurement.

Q: What is the isolation voltage of the KL3314?

A: Each KL3314 module is isolated for up to 500 V, enhancing safe operation.

Q: What is the default conversion time for the KL3314?

A: The KL3314 analog input module has a default conversion time of 250 ms.

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo