The Beckhoff FC3102-1258 is part of the FC Lightbus Cards series and features two fieldbus channels with an RS485 interface that support PROFIBUS DP, DP-V1, DP-V2, and PROFIBUS MC systems. This PCI plug-and-play card offers 4 kbytes DPRAM per channel, is galvanically isolated, and has bus connectors using two D-Sub sockets. It supports communication as both master and slave, allows up to 125 slaves per channel, and operates at a typical current consumption of 1000 mA with a 5 V supply.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC3102-1258 is a plug-and-play PCI fieldbus interface manufactured by Beckhoff within the FC Lightbus Cards series. Installed in a control PC, the card equips the system with direct PROFIBUS DP capability so that automation software can operate as a network master, a network slave, or both simultaneously. Two onboard D-Sub sockets provide separate channels that transmit PROFIBUS telegrams through differential RS485 signaling. By offloading protocol handling to dedicated hardware, the board frees the host CPU and maintains deterministic exchanges of process data between centralized control and distributed devices.

All logic on the card is powered from the PCI backplane at 5 V, and the circuitry typically draws 1000 mA, so cabinet power budgets can be planned accurately. A 32-bit bus width allows the operating system to map dual-ported RAM directly into linear address space for low-latency transfers. The galvanically isolated RS485 interface protects the PC ground from field potentials while sustaining the high-speed differential signaling required by PROFIBUS. Communication resources are split across two independent channels, enabling parallel control of distinct network segments without requiring another interface card.

Each channel can manage up to 125 PROFIBUS nodes, and the firmware supports a maximum payload of 244 bytes per slave, covering typical sensor, actuator, and drive data sets. The aggregated process image available to the host reaches 3 kbytes, ensuring that cyclic data from both channels fit within a single DMA frame. Local buffering is handled by a dual-ported memory block of 4 kbytes per channel, so telegrams can queue without stalling the PCI bus even at high update rates. Two status LEDs on each channel provide simple visual diagnostics during setup and service. These indicators help users observe channel activity and identify communication faults without opening diagnostic software. Separate visual feedback for each network segment also makes it easier to distinguish a localized connection issue from a card-level problem during routine operation.

Bus Connectors
2 x D-Sub sockets
Bus System
PROFIBUS DP, DP-V1, DP-V2, PROFIBUS MC
Communication Mode
Master and slave (mixed)
Current Consumption
1000 mA typ.
Diagnostics
2 LEDs per channel
Dpram Per Channel
4 kbytes
Fieldbus Channels
2
Fieldbus Interface
RS485
Isolation
Galvanically isolated
Max Data Per Slave
244 bytes
Max Process Image
3 kbytes
Max Slaves Per Channel
125
Pc Interface
Plug-and-play PCI
Pci Bus Width
32 bit
Supply Voltage
5 V

Frequently Asked Questions about FC3102-1258:

Q: What communication modes are available on the FC3102-1258 card?

A: The FC3102-1258 supports both master and slave communication modes, allowing mixed operation within PROFIBUS networks.

Q: What is the maximum data size per slave on the FC3102-1258?

A: This model offers a maximum of 244 bytes of data per slave, supporting efficient data handling for each connected device.

Q: How many bus connectors are present on the FC3102-1258?

A: The FC3102-1258 provides two D-Sub sockets for bus connections, enabling connection to multiple PROFIBUS devices.

Q: How many fieldbus channels does the FC3102-1258 support?

A: With two fieldbus channels, this card can manage communication on two separate PROFIBUS segments simultaneously.

Q: What type of PC interface does the FC3102-1258 use?

A: The FC3102-1258 is designed for plug-and-play PCI interface compatibility, making installation into a 32-bit PCI slot straightforward.


Internal Product Review

  • ‘‘The FC3102-1258 is a Beckhoff fieldbus card designed for PROFIBUS communication with 2 fieldbus channels. Galvanic isolation and mixed master/slave operation make the card especially capable in complex automation networks. Support for up to 125 slaves per channel stands out as a strong advantage for high-density distributed control.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo