EP2918-0032
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
-
In-Stock, Ships 3-5 Days
The EP2918-0032 digital input module supports TwinSAFE/Safety over EtherCAT protocol, features a bus interface with 2 x M8 sockets, accommodates eight outputs with a max current of 2A, and weighs approximately 470g. Part of the EP Digital Input Modules by Beckhoff, it boasts IP67 protection.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The EP2918-0032 TwinSAFE EtherCAT box engineered by Beckhoff has eight failsafe outputs. This EtherCAT box can accommodate up to 128 safe connections. The product has high ruggedness. This device's outputs are used for actuators with up to 24 VDC and 2 A. The unit has an IP 67 degree of protection. It uses M12 screw connectors for its signal connection. This EtherCAT box uses a TwinSAFE logic-capable component through FSoE to control its outputs.
The product's safety parameters adapt their functionality according to the respective safety requirements. This device is characterized by a simple replacement process for its parts. It adjusts its safety parameters when restarting safety applications and is compatible with the EL6910 TwinSAFE logic for added functionality. This EtherCAT box has a fine granular configuration of the test pulses of its channels. The product's standard outputs can be activated with a safe output signal and an integrated ANDing. This device's use is supported only after gaining an understanding of its documentation. The unit operation by the user is allowed in protected workspaces. Its installation is permitted in only machinery complying with the Machinery Directive.
This TwinSAFE EtherCAT box is powered by a SELV/PELV power supply with a maximum output voltage of 36 VDC. The product must at any time not be operated near high-frequency systems. This device is directly connected to any EtherCAT network using its integrated EtherCAT interface without the need for an additional coupler box. The unit is compactly sized at 126 x 30 x 26.5 mm. It has a simplified signal wiring when the manufacturer's preassembled cables are used.
Frequently Asked Questions about EP2918-0032:
Q: What must be done before the EP2918-0032 EtherCAT box is commissioned?
A: Wiring faults to the sensors of the EP2918-0032 EtherCAT box must be eliminated before it is commissioned.
Q: What devices should not be operated near the EP2918-0032 box?
A: Radiotelephones, radios, transmitters or high-frequency systems should not be operated near the EP2918-0032 box.
Q: What is the watchdog time of the EP2918-0032 EtherCAT box?
A: The watchdog time of the EP2918-0032 EtherCAT box varies from 2 ms. to 60 s.
Q: How is the status display of the EP2918-0032 EtherCAT box highlighted?
A: The status display of the EP2918-0032 EtherCAT box is highlighted using LEDs.
Q: How is the electrical isolation of the EP2918-0032 EtherCAT box done?
A: The electrical isolation of the EP2918-0032 EtherCAT box is done between the channels and the EtherCAT interface.