The EK1960-0008 EtherCAT coupler integrates PC functionality with an Intel Atom® Processor at 1.91 GHz, 2 GB DDR3 RAM, a replaceable 4 GB CFast card, and supports EtherCAT communication. Part of the EK EtherCAT Couplers series by Beckhoff, it operates at 24 V DC and features DIN rail mounting for easy installation.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The EK1960-0008 EK EtherCAT Coupler is an automation component designed specifically for advanced safety and high performance in various industries. This coupler is manufactured by Beckhoff, and it comes with 20 inputs and 24 outputs to connect directly with various field devices.

The EK1960-0008 coupler ensures operation reliability through its watchdog monitoring mechanism, with configurable watchdog timeout from a minimum of 2 ms up to a maximum of 60000 ms. This coupler is intended to operate in a permissible air pressure range of 750 hPa to 1100 hPa, thereby accommodating usage under varying altitudes and industrial environments. The acceptable storage temperature range of this coupler is quite broad as it ranges from -40°C to +70°C, which makes it eligible for storage for an extended period in uncontrolled conditions. The EMC and safety standard is also assured as this coupler meets EN 61000-6-2 for EMC immunity and EN 60664-1 (Degree of Pollution 2), which signifies it for electrically noisy and semi-contaminated environments. The supply voltage for this coupler is fixed at 24 VDC to support standard industrial power systems. The dimensions of this coupler are 230.5 mm (W) x 100 mm (H) x 58.6 mm (D) to support compact and cost-saving cabinet designs.

The EK1960-0008 is provided with a cable length of up to 30 meters from input to sensor by utilizing cables with a cross-sectional area of 0.75 mm². This coupler conforms to EN 60068-2-27 for shock resistance to sustain mechanical stress during setup or operation. The output process image in this coupler is adjusted in real-time by depending on the TwinSAFE configuration, so that there is precise control and safety coordination. In terms of installation conditions, this coupler supports an acceptable air humidity level of 5% to 95% non-condensing, which guarantees performance stability in wide humidity conditions.

Cable length between sensor and input
30 m (if cables with a cross-sectional area of 0.75 mm² are used)
Dimensions (W x H x D)
230.5 x 100 x 58.6 mm
EMC immunity
conforms to EN 61000-6-2
Fault reaction time
≤ watchdog times
Number of inputs
20
Number of outputs
24
Output process image
Dynamic, according to the TwinSAFE configuration in TwinCAT 3
Permissible air humidity
5% - 95%, non-condensing
Permissible air pressure
750 hPa - 1100 hPa
Permissible degree of pollution
conforms to EN 60664-1: Degree of pollution 2
Permissible storage temperature
-40 °C - +70 °C
Supply voltage
24 VDC
Watchdog time
min. 2 ms, max. 60000 ms

Frequently Asked Questions about EK1960-0008:

Q: How does TwinSAFE configuration improve system performance in EK1960-0008?

A: TwinSAFE enables real-time safety logic execution, ensuring precise fault response. It integrates with TwinCAT 3 to centralize safety control within the EtherCAT network.

Q: Why is the 30 m cable length between sensor and input significant?

A: This length allows greater flexibility in machine layout. It supports installations across larger areas without signal degradation, given a 0.75 mm² cable.

Q: What is the benefit of having 20 inputs and 24 outputs?

A: It supports multiple device connections, reducing the need for additional modules. This increases I/O density and simplifies wiring in compact systems.

Q: Why is EN 60664-1 (Degree of Pollution 2) compliance critical for EK1960-0008?

A: It ensures reliable operation in environments with limited non-conductive pollution. This makes it suitable for semi-controlled industrial enclosures.

Q: How does the watchdog time range contribute to safety operations in EK1960-0008?

A: It allows configurable system response times, ensuring timely action during faults. Longer durations offer flexibility, while shorter intervals enhance reaction speed.


Internal Product Review

  • ‘‘The EK1960-0008 EK EtherCAT Coupler delivers stable performance with 20 inputs, 24 outputs, and 30 m sensor cable support. Its watchdog timing between 2 ms and 60000 ms ensures system safety. This product is vital in safety-critical automation applications where fault response and configuration flexibility are essential.’’