4.94 based on 219 reviews

🙶 I have always received exceptional service and support in my many years of working with Wake Industrial. 🙷

EK1960-0000 Beckhoff

In-Stock, Ships 3-5 Days
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The EK1960-0000 coupler offers fast response with a 1 ms logic cycle and stable 24 VDC input. Its 500 mA E-bus power supports terminal communication efficiently. With IP20 protection and -25 °C to +55 °C temperature support, this unit is vital for compact, high-performance automation setups.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The Beckhoff's manufactured EK1960-0000 is an EtherCAT Coupler used in industrial automation systems where high-speed signal processing and space-efficient integration are needed. This coupler offers high-speed control through a minimum cycle time of about 1 millisecond, required in precise and critical operations.

This coupler integrates a high number of 20 digital inputs and 24 digital outputs, with an optional 4 relay outputs for further control capabilities. These I/O capabilities make this coupler suitable for applications that require a high density of signal connections within minimal space. This coupler allows efficient wiring between outputs and actuators with a 30-meter cable length, provided that 0.75 mm² cross-sectional area cables are used. The EK1960-0000 coupler comes with a watchdog timer that can be configured from 2 milliseconds to 60000 milliseconds, which allows adaptable safety and monitoring capabilities based on particular system needs. The EK1960-0000 EtherCAT coupler has a 24 VDC voltage supply and SELV/PELV-approved safety, thus providing a range of safe operating voltage from –15% to +20%. The internal 5V and up-to-500-mA E-bus power supplies of this coupler guarantee a stable power supply and communication reliability across connected EtherCAT terminals.

Physically, this EK1960-0000 coupler is compact and weighs approximately 500 grams, so that it can be accommodated in control cabinets with limited space. This coupler also possesses a protection rating of IP 20, according to IEC 60529, and can be used in environments with a pollution degree level of 2. This coupler’s input image is dynamic and is configured by TwinSAFE in TwinCAT 3 to allow precise mapping of safety functions. The working ambient temperature range of this coupler is from -25 °C to +55 °C, where it remains stable in operation with changing climate conditions.

Cable length between output and actuator
30 m (if cables with a cross-sectional area of 0.75 mm² are used)
E-bus power supply (5 V)
max. 500 mA
Input process image
Dynamic, according to the TwinSAFE configuration in TwinCAT 3
Minimum logic cycle time
approx. 1 ms
Number of inputs
20
Number of outputs
24 (+ 4 optional relay outputs)
Permissible ambient temperature (operation)
-25 °C - +55 °C
Permissible degree of pollution
conforms to EN 60664-1: Degree of pollution 2
Protection rating as per IEC 60529
IP 20
Shock resistance
conforms to EN 60068-2-27
Supply voltage (SELV/PELV)
24 VDC (–15% / +20%)
Watchdog time
min. 2 ms, max. 60000 ms
Weight
approx. 500 g

Frequently Asked Questions about EK1960-0000:

Q: How does the dynamic input process image benefit system configuration?

A: It allows real-time I/O allocation adjustments through TwinCAT 3. This enables efficient resource usage and flexible safety mappings.

Q: Why is a 500 mA E-bus power limit important for the EK1960-0000?

A: It ensures reliable power supply to connected EtherCAT terminals. This prevents voltage drops and supports stable communication.

Q: How does the 30 m cable length support field installation?

A: It allows installation of actuators far from the control cabinet. This flexibility reduces wiring complexity in distributed systems.

Q: What role does the watchdog timer play in EK1960-0000 operation?

A: It monitors system response times and triggers safety actions if delays occur. This enhances protection against communication failures.

Q: Why is SELV/PELV compliance important for this device?

A: It ensures user safety by limiting touch voltage levels. This compliance also aligns with electrical safety standards in automation.