3IF661.9 B & R Automation
Wake Industrial LLC is not an authorized distributor of this product.
The B & R Automation 3IF661.9 is a slave module in the System 2005 Controllers series featuring a PROFIBUS-DP protocol and an RS485 interface. It uses an IF1 application interface, a 9-pin DSUB socket connector, and supports a maximum data transfer rate of 12 Mbit/s. This module includes an input filter and protective circuit, is powered by up to 2 W, and operates with an external T-connector for bus termination.
Internal Product Review
The 3IF661.9 is a B & R Automation System 2005 controller interface module for PROFIBUS-DP communication, using the ASIC SPC3 controller. The 1 x RS485 interface and 12 Mbit/s transfer rate support stable, responsive fieldbus integration in automation systems. As a slave module with max. 2 W power consumption, 3IF661.9 is an efficient and well-executed option for controller expansion.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 3IF661.9 communication module is produced by B&R Automation for the System 2005 Controllers series. Installed in compatible base units, it equips a controller with a dedicated PROFIBUS-DP slave channel so the host can exchange cyclic data with higher-level PLCs or process networks. By acting as an add-on card, it off-loads fieldbus handling from the main CPU and supports distributed I/O, drive coordination, and diagnostic data acquisition within factory automation cells.
The module communicates exclusively over the PROFIBUS-DP fieldbus protocol, and its physical layer is built on a single 1 x RS-485 differential port that provides noise-tolerant transmission over shielded twisted pair. Data exchanges can be scheduled at rates up to 12 Mbit/s, allowing the station to keep pace with fast digital I/O or motion feedback. Bus arbitration, diagnostic telegram handling, and watchdog timing are executed locally by the ASIC SPC3 controller, reducing load on the System 2005 CPU. Within every network cycle, the board behaves as a slave, which means it does not issue global tokens but instead waits for commands from the class 1 master while still supporting user parameterization and alarm forwarding.
Electrical requirements are modest: the card draws Max. 2 W from the System 2005 backplane, so thermal impact inside CP260, IF260, or IF060 racks is minimal. Field wiring is performed through a 9-pin DSUB socket, and correct line impedance is established by an external T-connector that houses the mandatory PROFIBUS termination resistors. An input filter and protective circuit are present to suppress transients before they reach the IF1 application interface, preserving data integrity. Runtime buffers consist of 1.5 KB of dual-port RAM that stores parameter sets and cyclic process data between polls.