BK1250

  • Rated 4.4 (10 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
    In-Stock, Ships 3-7 Days
  • Call for Expedited Shipping and Product Condition Options
BK1250 is an EK1xxx series EtherCAT coupler manufactured by Beckhoff. This coupler weighs approx. 55 g , and operates with 100 Mbaud data transfer rates and 24 V DC power supply.
✓ In-Stock!

Wake Industrial LLC is not an authorized distributor of this product.

BK1250

  • Rated 4.4 (10 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
    In-Stock, Ships 3-7 Days
  • Call for Expedited Shipping and Product Condition Options
BK1250 is an EK1xxx series EtherCAT coupler manufactured by Beckhoff. This coupler weighs approx. 55 g , and operates with 100 Mbaud data transfer rates and 24 V DC power supply.
Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

The Beckhoff BK1250 is an EtherCAT Bus Coupler. This model is considered in the construction of control systems where a mix of standard Bus Terminals (KLxxxx) and EtherCAT Terminals (ELxxxx) is desired in a bus station. This coupler is designed in the terminal housing and requires no cables for its deployment. With this device, you will be able to implement cost-effective and compact control solutions without investing any additional hardware resources.

The BK1250 is deployed on a DIN-rail with E-bus terminals on the left and K-bus terminals on the right. It is a simple solution to combine more than 300 standard Bus Terminals (including standard special terminals). It has a large bandwidth and better communication speed than most other EtherCAT terminals. A single BK1250 unit can accommodate 64 x K-Bus Terminals. Using a K-bus extension, even better channel density of up to 255 terminals can also be achieved. Unlike BK1120 and BK1150, the BK1250 has no physical Ethernet port as it utilizes the E-bus contacts to provide bus intra-bus connectivity. This bus coupler is a smart device as it performs all the control and monitoring tasks related to the associated Bus Terminals.

This EtherCAT Bus Coupler requires 24VDC power supply and draws a maximum current of 200 mA and it is designed to be mounted on 35 mm mounting rails as defined by EN 60715. The front panel of the coupler contains all the power supply spring terminals and diagnostic LEDs. In addition to basic diagnostics, dedicated LEDs are also provided to indicate the I/O Run status and I/O Error status of the K-bus. This coupler has a protective earth power contact which can ground up to 125 A short-circuit current to ensure the safety of the system.

 

  • bk1250
  • BK125O

BK1250 Technical Specifications

Data Transfer Rates: 100 Mbaud
Diagnostic LEDs: Avaliable
Maximum Current : 200 mA
Power Supply Required : 24 VDC
Protective Earth Power Contact : Equipped
Short-Circuit Current: up to 125 A
Mounting: 35 mm mounting rails
Operating Temperature Range: 0 to +50 degree centigrade
Storage and Transportation Temperature Range: (-25 to +75) degree centigrade
Maximum Installation Elevation: 1000 MSL

Frequently Asked Questions about BK1250


Q: Can the BK1250 be used with both standard Bus Terminals (KLxxxx) and EtherCAT Terminals (ELxxxx)?

A: Yes, the BK1250 allows for the integration of both KLxxxx and ELxxxx terminals within a bus station, eliminating the need for cables during its setup.

Q: How does the BK1250 differentiate from the BK1120 and BK1150 in terms of Ethernet connectivity?

A: Unlike the BK1120 and BK1150, the BK1250 lacks a physical Ethernet port, utilizing E-bus contacts instead to ensure intra-bus connectivity.

Q: How many K-Bus Terminals can a single BK1250 unit accommodate?

A: A single BK1250 unit can support up to 64 K-Bus Terminals. However, with a K-bus extension, it can achieve a channel density of up to 255 terminals.

Q: What power supply is needed for the BK1250 EtherCAT Bus Coupler?

A: The BK1250 requires a 24VDC power supply and has a maximum current draw of 200 mA.

Q: Are there any diagnostic LEDs on the BK1250?

A: Yes, the front panel of the BK1250 has diagnostic LEDs, including dedicated ones to display the I/O Run status and I/O Error status of the K-bus.

Internal Product Review

  • ‘‘The BK1250, ideal for control systems, seamlessly combines many terminals. Superior in bandwidth and speed, it supports up to 255 K-Bus Terminals with extensions. Efficient, with smart control features.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo