SC4210-01000

Ask for Availability

Preparing your secure checkout page...

The Danaher SC4210-01000 is part of the NEXTDRIVE Frequency Drives series and features an input voltage range of 3 x 200 V to 3 x 480 V with auto-ranging capability. Its output voltage reaches up to 3 x 460 V (VRMS) and supports an output frequency range of 0 to 4000 Hz. Short-circuit protection safeguards circuits up to 5000 ARMS symmetrical.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The SC4210-01000 Frequency Drive exists as an industrial automation product of Danaher. The drive works with input voltage in the range of 230 VAC. Single-phase power functions within a voltage range of ±10% from the nominal value. The drive produces 10 HP at its maximum operational capacity. The motor capacity reaches 7.46 kW under this condition.

The frequency input levels of SC4210-01000 frequency drive vary between 47.5 Hz and 63 Hz. It works best when using either 50 Hz or 60 Hz as standard input frequencies. The drive provides output frequency control between 0.1 Hz and 120 Hz. Output frequency operations can be programmed through 0.1 Hz increments. Full load current measures 28.0 A at 230 VAC. The control device operates in open-loop mode with scalar V/Hz functions. The efficiency operates at 96% when performing full load operations. The SC4210-01000 frequency drive is rated amount by 150 percent when operating at a current level exceeding. This shows that it draws 42 A for 60 seconds. The drive carrier frequency defaults to 4 kHz. This drive automatically operates between frequencies 2 kHz and 12 kHz according to requirements. Operating temperature spans 0°C to 40°C. This range avoids derating issues. Storage temperature extends from -20°C to 65°C. The forced-air fan generates 50 CFM while performing cooling operations.

Users can program the SC4210-01000 frequency drive to operate acceleration sequences from 0.1 seconds up to 600 seconds. The deceleration time selection extends from 0.1 seconds to 600 seconds. Both adjust in 0.1-second increments. Protection includes overcurrent exceeding 200% instantly. The bus will experience overvoltage when it exceeds 400 VDC. The bus undervoltage system turns on when the bus voltage drops below 190 VDC. The system turns on Overtemperature protection at a heatsink temperature exceeding 85°C. The enclosure meets IP20 standards for indoor use.

Continuous current overload
120% unlimited
Control mode
Open-loop scalar V/Hz
Cooling method
Forced-air fan
Efficiency at full load
96%
Full-load current
28 A
Input voltage range
200–480 V AC, 3‑phase auto-ranging
Operating temperature
0 °C to 40 °C
Output frequency range
0–4000 Hz
Output voltage range
0–460 V per phase VRMS
Overtemperature protection threshold
> 85 °C heatsink
Peak current overload
150% for 1 min/10 min cycle
Short-circuit protection
Up to 5000 A RMS symm., 480 V max
Storage temperature
–20 °C to 65 °C

Frequently Asked Questions about SC4210-01000:

Q: How does the SC4210-01000 manage heat dissipation effectively?

A: The SC4210-01000 uses a forced-air cooling fan generating 50 CFM to dissipate heat efficiently. This ensures stable operation under full load without thermal overload.

Q: What advantage does a carrier frequency range up to 12 kHz offer in the SC4210-01000?

A: A carrier frequency up to 12 kHz in SC4210-01000 reduces motor noise and enhances signal resolution. This supports quieter and smoother motor performance.

Q: Why is scalar V/Hz control used in the SC4210-01000 frequency drive?

A: Scalar V/Hz control in the SC4210-01000 offers simple speed control with high reliability. It's ideal for applications not requiring precise torque regulation.

Q: Why is the SC4210-01000 designed to operate in open-loop mode?

A: Open-loop mode in SC4210-01000 eliminates the need for feedback devices. This simplifies installation and reduces cost in standard speed control applications.

Q: How does the SC4210-01000 handle momentary current surges?

A: The SC4210-01000 is rated for 150% overload for 60 seconds. It handles short-term overcurrent conditions without tripping, supporting demanding industrial tasks.


Internal Product Review

  • ‘‘The SC4210-01000 frequency drive by Danaher ensures reliable motor control. It features open-loop scalar V/Hz functionality, 50 CFM fan cooling, and overload handling of 150% for 60 seconds. It delivers 7.46 kW motor power, carrier frequency up to 12 kHz, and IP20-rated protection.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo