4.95 based on 202 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

MSS482A-0200-FA-N0CN-NNNN Bosch Rexroth Indramat

Ask for Availability

Current response time:
6 Minutes 32 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat MSS482A-0200-FA-N0CN-NNNN is part of the MSS Synchronous IndraDyn H Motors series and operates with three motor phases. It provides an axial attractive force of 1100 Newtons and a radial attractive force of 659 Newtons, with a degree of protection rated at IP00. The motor supports a required coolant flow of 4.0 liters per minute and is equipped with both KTY84-130 and SNM.150.DK.* temperature sensors.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The Bosch Rexroth Indramat MSS482A-0200-FA-N0CN-NNNN is a water-cooled stator module from the MSS Synchronous IndraDyn H Motors series. In multi-axis machining centers or gantry systems, this component forms the stationary half of a direct-drive synchronous motor, providing the electromagnetic field that propels a matching rotor without gear reduction. The arrangement supports the precise speed and position regulation required for high-accuracy industrial automation tasks. Because the coils are embedded directly in the machine frame, the design shortens the drivetrain and reduces the number of mechanical parts requiring maintenance.

Magnetic forces generated by the winding stack impose an axial pull of 1100 N on the machine bearing seats and a radial pull of 659 N toward the stator yoke. Guides, spacers, and bearing supports must be sized to withstand these loads during operation. The winding set has 3 symmetrical phases, enabling standard IndraDrive inverters to supply sinusoidal current. Power conductors enter through an opening sized for a 30 mm cable diameter and should use copper leads with a cross-sectional area of 16.0 mm² to keep electrical losses within thermal limits. With a protection category of IP00, the module must be installed inside a suitable enclosure so that live parts remain shielded from accidental contact.

Liquid cooling removes heat produced by copper losses in the winding. A coolant flow of 4.0 L/min must pass through the internal channels, and system pumps may supply up to 6 bar without exceeding the housing pressure rating. Under nominal conditions, the stator introduces a hydraulic resistance of 1.2 bar, which must be included when calculating total pressure loss in the cooling circuit. Mechanical attachment uses 18 M8 fixing threads with a depth of 16 mm arranged around the circumference. A single M8 grounding stud and dedicated sensor terminals support connection of the integrated SNM.150.DK temperature sensor and an external KTY84-130 sensor using 0.5 mm² and 0.25 mm² leads, respectively.

Axial Attractive Force
1100 N
Connection Strand Diameter
30 mm
Degree Of Protection
IP00
External Temp Sensor
KTY84-130
Ground Threads
1 x M8 x 16 mm Deep
Integrated Temp Sensor
SNM.150.DK.*
Kty Wire Cross-section
0.25 mm²
Max Coolant Pressure
6 bar
Motor Phases
3
Power Wire Cross-section
16.0 mm²
Pressure Drop
1.2 bar
Radial Attractive Force
659 N
Required Coolant Flow
4.0 l/min
Snm Wire Cross-section
0.5 mm²
Stator Fixing Threads
18 x M8 x 16 mm Deep

Frequently Asked Questions about MSS482A-0200-FA-N0CN-NNNN:

Q: What is the maximum axial attractive force supported by the MSS482A-0200-FA-N0CN-NNNN motor?

A: The MSS482A-0200-FA-N0CN-NNNN motor can handle an axial attractive force of up to 1100 N.

Q: What type of external temperature sensor is featured in the MSS482A-0200-FA-N0CN-NNNN?

A: This model uses a KTY84-130 external temperature sensor for monitoring motor temperatures.

Q: What is the degree of protection for the MSS482A-0200-FA-N0CN-NNNN motor?

A: The degree of protection for this motor is rated as IP00, indicating no protection against dust or water.

Q: How much coolant flow is required for the MSS482A-0200-FA-N0CN-NNNN motor?

A: The required coolant flow for this motor is 4.0 liters per minute.

Q: How many motor phases does the MSS482A-0200-FA-N0CN-NNNN have?

A: This motor is designed with three motor phases for electrical operation.


Internal Product Review

  • ‘‘The MSS482A-0200-FA-N0CN-NNNN is a Bosch Rexroth Indramat synchronous motor with a 3-phase configuration and IP00 protection. A required coolant flow of 4.0 l/min with 6 bar maximum coolant pressure supports stable thermal management in continuous-duty installations. Integrated SNM.150.DK.* and external KTY84-130 temperature sensing add valuable monitoring capability, making the motor a strong choice for tightly controlled motion systems.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo