DDS03.2-W030-BE12-01-FW

  • {{ 'Rated ' + avg.toFixed(1) + ' (' + ratingCount + ' total ratings)' }}
  • {{ message }}
DDS Series Drive Controller manufactured by Indramat, Bosch, Rexroth. This Controller features a Rated Current of 30A along with a Cooling Style of Air, control cab. ext. air (intern).

DDS03.2-W030-BE12-01-FW

  • {{ 'Rated ' + avg.toFixed(1) + ' (' + ratingCount + ' total ratings)' }}
  • {{ message }}
DDS Series Drive Controller manufactured by Indramat, Bosch, Rexroth. This Controller features a Rated Current of 30A along with a Cooling Style of Air, control cab. ext. air (intern).

Warranty
1 Year Wake Industrial Warranty Included
Shipping
Worldwide shipping via DHL, UPS, and Fedex
Exchange
Call to find out about our exchange credit for your defective unit.
Sell Us Your Surplus
Have a DDS03.2-W030-BE12-01-FW to sell?
To Speak to a sales representative for pricing and lead time:

Product Description

The DDS Indramat Rexroth series is smart, safe and efficient. These versatile high performance drives can be found with single power unit and have modular AC servo design.

DDS03.2-W030-BE12-01-FW has the ability to provide Motor feedback via digital servo and Resolver feedback. It utilizes SERCOS interface for operating drive controller via a LWL fiber optic cable so as to communicate between drive and control. Sercos also supplies inputs for the estimation of reference switches, travel range limit switches and sensor inputs.

Function id 01 is fixed and determined by the manufacturer and Firmware needs to be connected separately to this system. The firmware fixes the troubles and faults in drive controller; also it is integrated in the Software Plugin. Service Cable IKS0391 is needed when you use ANALOG interface, this helps in parameterization on the connected Terminal Display to it. The mass of DDS03.2 series controller is 5.5 kg. The power cable length is attached to X4 slot of basic unit and is around 75 meters. Shielded motor power cables must be used and avoid any interference with other cables.

The heat exchanger in the system must be installed properly in order to avoid condensation of moisture accumulation within the cabinet and which damages drive components. Hence well sealed control cabinet must be used and inside heat cooling system is utilized. It is advised, not to switch off the heat-exchanging unit even when the plant is switched-off, hence the drive components and control cabinet start coming at equal temperatures.

The allowed maximum overall heat of this complete system must be between 0 and 45 degree Celsius. Bosch informs that the maintenance temperature of the drive controller also needs to be between 30-85 ºC.

  • DDS 03.2-W030-BE12-01-FW
  • DDS03-2-W030-BE12-01-FW
  • DDS03.2-W030-BE12-01
  • DDS032-W030-BE12-01-FW
  • DDS032W030BE1201FW
  • DDS3.2-W030-BE12-01-FW
  • DDSO3.2-W030-BE12-01-FW

DDS03.2-W030-BE12-01-FW Technical Specifications

Digital and Modular Servo Drive Unit DDS
Series 3
Version 2
Cooling Style Air, control cab. ext. air (intern)
Rated Current 30A
Motor Feedback Factory Assigned
Communications Module Factory Assigned
Function I.D. 12