CDB Series Drive Controller manufactured by Indramat, Bosch, Rexroth. This Drive Controller features Configuration Options like a Master Communication of SERCOS Interface along with a Safety Option of With Safety Technology I/O.

CDB01.1C-SE-EN1-EN1-EN2-EN2-S1-S-NN-FW

  • {{ 'Rated ' + avg.toFixed(1) + ' (' + ratingCount + ' total ratings)' }}
  • {{ message }}
CDB Series Drive Controller manufactured by Indramat, Bosch, Rexroth. This Drive Controller features Configuration Options like a Master Communication of SERCOS Interface along with a Safety Option of With Safety Technology I/O.

Warranty
1 Year Wake Industrial Warranty Included
Shipping
Worldwide shipping via DHL, UPS, and Fedex
Exchange
Call to find out about our exchange credit for your defective unit.
Sell Us Your Surplus
Have a CDB01.1C-SE-EN1-EN1-EN2-EN2-S1-S-NN-FW to sell?
To Speak to a sales representative for pricing and lead time:

Product Description

CDB01.1C-SE-EN1-EN1-EN2-EN2-S1-S-NN-FW General Information


The Rexroth/Indramat IndraDrive CDB01.1C-SE-EN1-EN1-EN2-EN2-S1-S-NN-FW that is a converter used to control automation systems in manufacturing and service facilities. This is an extremely reliable and quality drive for the price. It is amongst the best drive available to help automate you manufacturing or service system. Its price to performance ratio is unparalleled when compared to other drive brands on the market. For more information regarding this drive or any other drive, go to the CDB series to see the entire selection of CDB drives.

The CDB01.1C-SE-EN1-EN1-EN2-EN2-S1-S-NN-FW is equipped with SERCOS interface, an option 1 RSF/HSF encoder, an option 2 RSF/HSF encoder, an option 3 IndraDyn/Hiperface/1Vpp/TTL encoder, an option 4 IndraDyn/Hiperface/1Vpp/TTL, safety I/O technology, and a standard control panel. It has 1 analog input, 0 to 4 digital outputs, 2 analog outputs, and 1 N/O relay contact. The serial interface is associated with the X2 port, the relay contacts connect at X11/X12, the digital and analog I/O are at the X31/X32 ports, and the interface for the control panel connects at the H1 port. This HCS drive has 3 integrated switching frequencies: 2kHz, 4kHz, and 8kHz. For more information or to submit an RFQ for this drive, contact us here at WakeIndustrial via phone or email.

Why buy from Wake Industrial?

If you would like to place an RFQ or just ask a question, we have a full time support and sales staff that would be happy to help you. You can contact us via email or phone. WakeIndustrial is a world leader in the sale of CDB drives and many other automation parts and brands.

CDB01.1C-SE-EN1-EN1-EN2-EN2-S1-S-NN-FW FAQ


Question: Should protective diode be used when using this drive?
Answer: Yes, you should use protective diode to protect against incorrect connection and polarity reversal in the power supply at X31.8.

Question: What connections are configurable as either digital inputs or outputs?
Answer: The X32.6, X32.7, and X32.8 connections can be figured as digital I/O.

Question: Where is the travel range limit switch found?
Answer: The travel range limit switch is found at the X31.5 connection .

Question: What connection is the RS232 serial interface associated with?
Answer: The serial interface is associated to the X2 connection.

CDB for Explosion Proof - Operating Manual.pdf
CDB for Explosion Proof - Project Planning Manual.pdf
CDB Synchronous Drives.pdf
CDB Type Code Explanation.pdf

  • CDB 01.1C-SE-EN1-EN1-EN2-EN2-S1-S-NN-FW
  • CDB01.1C-SE-EN1-EN1-EN2-EN2-S1-S-NN
  • CDB011CSEEN1EN1EN2EN2S1SNNFW
  • CDB1.1C-SE-EN1-EN1-EN2-EN2-S1-S-NN-FW
  • CDBO1.1C-SE-EN1-EN1-EN2-EN2-S1-S-NN-FW

CDB01.1C-SE-EN1-EN1-EN2-EN2-S1-S-NN-FW Technical Specifications

Product: CDB
Other Design: None
Configuration Options: Configurable
Master Communication: SERCOS Interface
Option 1: Encoder HSF / RSF
Option 2: Encoder HSF / RSF
Option 3: Encoder EnDat 2.1 / 1 Vpp / TTL
Option 4: Encoder EnDat 2.1 / 1 Vpp / TTL
Safety Option: With Safety Technology I/O
Control Panel: Standard